Parameters

Parameter Default Value
IMAG IMAG_VGW SPEC
OBJECT DUMMY DUMMY "FIELDCHECK"
RA !STATS.RA !STATS.RA DUMMY
DEC !STATS.DEC !STATS.DEC DUMMY
EQUINOX 2000.0 2000.0 DUMMY
PA 0.0 0.0 -
AG_SELECT - MANUAL -
I_BOTTOM - 2200 -
DATASET_ID - - "DS0000"
EXPTIME - - NOP
FILTER - - NOP
SLITX - - NOP
SLITY - - NOP
DX - - 0.0
DY - - 50.0

Description

This command points the telescope to RA and DEC and sets the position angle to PA$^{\circ}$. It also pulls out the AG-probe to $r=90.0$ if $r<90.0$.

Last Update

2002/03/04

Author

George Kosugi, Fumihide Iwamuro, Kentaro Motohara
next up previous
Next: SETUPOBE Up: Abstract Command References Previous: RESETUPOBE